WinCamD-IR-BB – Broadband 2 to 16 µm MWIR/FIR Beam Profiler

USB 3.0
Product ID: S-WCD-IR-BB-30

Contact us for availability

Broadband 2 to 16 µm Beam Profiler

Port-powered USB 3.0

Features

  • Broadband 2 to 16 µm VOx microbolometer
  • 640 x 480, 10.88 x 8.16 mm active area
  • 17 µm pixels
  • Port-powered USB 3.0, 3 m screw locking cable
  • 30 FPS update rate (7.5 FPS for export)
  • Integrated shutter for automated NUC
  • 14-bit ADC
  • 14 ms time constant – Pulsed lasers with PRR = 1 kHz appear as CW
  • No chopper/TEC
  • Parallel capture on multiple cameras
  • M² measurements

Applications

  • MWIR/FIR/CO₂ laser profiling
  • Field servicing of MWIR/FIR/CO₂ lasers and laser-based systems
  • Optical assembly & instrument alignment
  • Beam wander & logging
  • M² measurement with available M2DU stage

 

Please note:

This product requires 64-bit Windows 7, 8/8.1, or 10

SpecificationDetail
SensorVanadium oxide (VOx) microbolometer
WavelengthBroadband MWIR/FIR: 2 to 16 µm
Pixel Count, H x V307 kilopixels, 640 x 480
Image Area10.88 x 8.16 mm
Pixel Dimension17 x 17 µm
Min. Beam (10 pixels)~170 µm
Shutter TypeRolling
Max. Full Frame Rate30 Hz (7.5 for export)
Signal to RMS Noise≥1000:1
Opt./Elec. dB30/60
ADC14-bit
Measurable SourcesCW beams, pulsed sources (auto-trigger sync)
Measured Beam PowersSee the Approximate Saturation Power Limits graph
Manual Beam AttenuationProvided 1" ND-1 and ND-2 reflective Germanium filters. See app note for more info.
Displayed Profiles2-D & 3-D plots
10, 16, 256 or max colors or gray. Contoured display at 10 and 16 color.
Measured & Displayed Profile ParametersRaw and smoothed profiles
[Triangular running average filter up to 10% FWHM]
Beam DiameterDiameter at two user set Clip levels
Gaussian & Second Moment beam diameters
Equivalent diameter above a user defined Clip level
Equivalent Slit and Knife Edge diameters
Beam FitsGaussian & Top Hat profile fit & % fit
Equivalent Slit profile
Beam EllipticityMajor, Minor & Mean diameters. Auto-orientation of axes.
Centroid PositionRelative and absolute
Intensity Weighted Centroid and Geometric Center
Beam Wander Display and Statistics
Measurement Accuracy5 µm processing resolution for interpolated diameters
Absolute accuracy is beam profile dependent - ~10 µm accuracy is frequently achievable
Centroid accuracy is also beam dependent. It can be as good as ±10 µm since it is arithmetically derived from all pixels above the centroid clip level.
Processing OptionsImage & profile Averaging, 1, 5, 10, 20, Continuous.
Background Capture and Subtraction.
User set rectangular Capture Block for capture
User set or Auto ellipse Inclusion region with beam tracking for processing
*.ojf files save all WinCamD custom settings for particular test configurations
Pass/Fail displayOn-screen selectable Pass/Fail colors. Ideal for QA & Production.
Log data and statisticsMin., Max., Mean, Standard Deviation, to 4096 samples
Relative Power MeasurementRolling histogram based on user's initial input. Units of mW, µJ, dBm, % or user choice (relative to a reference measurement input)
FluenceFluence, within user defined area
CertificationRoHS, WEEE, CE
Multiple CamerasUp to 4 cameras, parallel capture.
1 to 8 cameras, serial capture.
Camera Dimensions‚ Width x Height x Depth73 x 73 x 52 mm
Optical depth from housing/filter to sensor ±0.2 mm15.5 mm
Mounting1/4"-20 holes aligned with sensor center
Weight (Camera with 1" NDL-2 Ge filter)422 g (14.9 oz)


Product specifications are subject to change without notice

 

 